Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29.764
Filtrar
1.
Langenbecks Arch Surg ; 409(1): 118, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38600407

RESUMO

PURPOSE: Due to improved survival of esophageal cancer patients, long-term quality of life (QoL) is increasingly gaining importance. The aim of this study is to compare QoL outcomes between open Ivor Lewis esophagectomy (Open-E) and a hybrid approach including laparotomy and a robot-assisted thoracic phase (hRob-E). Additionally, a standard group of healthy individuals serves as reference. METHODS: With a median follow-up of 36 months after hRob-E (n = 28) and 40 months after Open-E (n = 43), patients' QoL was assessed using the European Organization for Research and Treatment of Cancer (EORTC) QoL Questionnaire Core 30 (QLQ-C30) and the EORTC Esophagus specific QoL questionnaire 18 (QLQ-OES18). RESULTS: Patients showed similar clinical-pathological characteristics, but hRob-E patients had significantly higher ASA scores at surgery (p < 0.001). Patients and healthy controls reported similar global health status and emotional and cognitive functions. However, physical functioning of Open-E patients was significantly reduced compared to healthy controls (p = 0.019). Operated patients reported reduced role and social functioning, fatigue, nausea and vomiting, dyspnea, and diarrhea. A trend towards a better pain score after hRob-E compared to Open-E emerged (p = 0.063). Regarding QLQ-OES18, hRob-E- and Open-E-treated patients similarly reported eating problems, reflux, and troubles swallowing saliva. CONCLUSIONS: The global health status is not impaired after esophagectomy. Despite higher ASA scores, QoL of hRob-E patients is similar to that of patients operated with Open-E. Moreover, patients after hRob-E appear to have a better score regarding physical functioning and a better pain profile than patients after Open-E, indicating a benefit of minimally invasive surgery.


Assuntos
Neoplasias Esofágicas , Robótica , Humanos , Qualidade de Vida , Esofagectomia , Inquéritos e Questionários , Neoplasias Esofágicas/cirurgia , Dor
2.
Neurosurg Rev ; 47(1): 150, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38600417

RESUMO

Cerebral aneurysm is a life-threatening condition, which requires high precision during the neurosurgical procedures. Increasing progress of evaluating modern devices in medicine have led to common usage of robotic systems in many fields, including cranial aneurysm operations. However, currently no systematic review describes up-to date knowledge of this topic. Following PRISMA guidelines, we have independently screened and extracted works from seven databases. Only studies fulfilling inclusion criteria were presented in this study. Device used, operation time, complications, aneurysm type and patient demographics were extracted from each work. We identified a total of 995 articles from databases. We have found six original works and one supplementary article eligible for this synthesis. Majority of works (4/6) have implemented CorPath GRX in cerebral aneurysm procedures. The procedures involved diverse aneurysm locations, utilizing flow diverters, stents, or coiling. One study described implementation of robot-assist on 117 patients and compared results to randomized clinical trials. One work with a small patient cohort described use of the magnetically-controlled microguidewire in the coiling procedures, without any complications. Additionally, one case-series study described use of a robotic arm for managing intraoperative aneurysm rupture. Currently, robotical devices for cerebral aneurysm treatment mainly lack jailing and haptic feedback feature. Further development of these devices will certainly be beneficial for operators and patients, allowing for more precise and remote surgeries.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Aneurisma Intracraniano/cirurgia , Resultado do Tratamento , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Stents , Estudos Retrospectivos
3.
BMC Health Serv Res ; 24(1): 523, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664810

RESUMO

BACKGROUND: People with physical disabilities due to disease or injury face barriers to their daily activities and participation in society. Many depend on formal or informal caregivers for assistance to live independently. However, future healthcare challenges due to demographic changes threaten access to home care and assistants. Assistive technologies, such as robots for physical assistance, can support the independence and autonomy of people with physical disabilities. This study explore Norwegian care-receivers' perceptions of using robot assistance in their homes, including preferences for tasks acceptable or unacceptable for robot assistance and the underlying reasons. METHOD: Purposive sampling was employed to recruit 18 participants, aged between 18 and 77 years, with differences in physical function including diagnoses such as stroke, spinal cord injury, amputations, and muscular dystrophy. Qualitative data were gathered through four focus group interviews wherein participants watched videos featuring a humanoid assistive robot, EVEr3. The collected data underwent analysis using reflexive thematic analysis. RESULTS: Three themes with associated sub-themes were constructed: (a) How a robot could assist in daily life, (b) The robot's appearance and functionality, and (c) Concerns about having a robot as an assistant. The participants welcomed the idea of a future robotic assistant in areas that may contribute to an increased feeling of independence and autonomy. CONCLUSION: A robot assisting in activities of daily living would need to be individually customized to meet the needs of each user in terms of which tasks to assist with, how to assist in these defined tasks, and how it is controlled.


Assuntos
Cuidadores , Pessoas com Deficiência , Grupos Focais , Pesquisa Qualitativa , Robótica , Tecnologia Assistiva , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Pessoas com Deficiência/psicologia , Pessoas com Deficiência/reabilitação , Noruega , Cuidadores/psicologia , Adolescente , Atividades Cotidianas , Adulto Jovem
4.
JMIR Aging ; 7: e52443, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38623717

RESUMO

Background: Interventions and care that can evoke positive emotions and reduce apathy or agitation are important for people with dementia. In recent years, socially assistive robots used for better dementia care have been found to be feasible. However, the immediate responses of people with dementia when they are given multiple sensory modalities from socially assistive robots have not yet been sufficiently elucidated. Objective: This study aimed to quantitatively examine the immediate emotional responses of people with dementia to stimuli presented by socially assistive robots using facial expression analysis in order to determine whether they elicited positive emotions. Methods: This pilot study adopted a single-arm interventional design. Socially assistive robots were presented to nursing home residents in a three-step procedure: (1) the robot was placed in front of participants (visual stimulus), (2) the robot was manipulated to produce sound (visual and auditory stimuli), and (3) participants held the robot in their hands (visual, auditory, and tactile stimuli). Expression intensity values for "happy," "sad," "angry," "surprised," "scared," and "disgusted" were calculated continuously using facial expression analysis with FaceReader. Additionally, self-reported feelings were assessed using a 5-point Likert scale. In addition to the comparison between the subjective and objective emotional assessments, expression intensity values were compared across the aforementioned 3 stimuli patterns within each session. Finally, the expression intensity value for "happy" was compared between the different types of robots. Results: A total of 29 participants (mean age 88.7, SD 6.2 years; n=27 female; Japanese version of Mini-Mental State Examination mean score 18.2, SD 5.1) were recruited. The expression intensity value for "happy" was the largest in both the subjective and objective assessments and increased significantly when all sensory modalities (visual, auditory, and tactile) were presented (median expression intensity 0.21, IQR 0.09-0.35) compared to the other 2 patterns (visual alone: median expression intensity 0.10, IQR 0.03-0.22; P<.001; visual and auditory: median expression intensity 0.10, IQR 0.04-0.23; P<.001). The comparison of different types of robots revealed a significant increase when all stimuli were presented by doll-type and animal-type robots, but not humanoid-type robots. Conclusions: By quantifying the emotional responses of people with dementia, this study highlighted that socially assistive robots may be more effective in eliciting positive emotions when multiple sensory stimuli, including tactile stimuli, are involved. More studies, including randomized controlled trials, are required to further explore the effectiveness of using socially assistive robots in dementia care.


Assuntos
Demência , Robótica , Humanos , Feminino , Idoso de 80 Anos ou mais , Projetos Piloto , Emoções/fisiologia , Felicidade
5.
BMC Urol ; 24(1): 92, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643097

RESUMO

PURPOSE: This study aimed to investigate the effects of two different positions on lower extremity hemodynamics during robot-assisted laparoscopic radical prostatectomy (RARP) for prostate cancer. METHODS: A total of 196 patients who underwent RARP in our hospital from February 2020 to March 2022 were included in this study. Among them, 98 patients who underwent surgery with the Trendelenburg position and split-leg position with calf reverse arch from March 2021 to March 2022 were assigned to the observation group, while 98 patients who underwent surgery with the Trendelenburg position and low lithotomy position from February 2020 to February 2021 were assigned to the control group. Using an ultrasound diagnostic instrument to detect the internal diameter, mean blood flow velocity, and mean blood flow volume of the left deep femoral vein at different times, such as the supine position (T0), after 5 minutes of placing the patient in the leg spilt or low lithotomy position (T1), after 5 minutes of pneumoperitoneum (T2), after 5 minutes of head-down tilt or head-down tilt and calf reverse arch (T3), 1.5 hours after the start of surgery (T4), before the removal of CO2 gas (T5), and before the patient left the operating room (T6). As well as the patency of deep venous blood flow in both lower extremities before leaving the operating room, RESULTS: After establishment of pneumoperitoneum, the internal diameter of the deep femoral vein increased significantly, while the mean blood flow velocity and mean blood flow volume decreased significantly in both groups(T0) (P<0.001). With the prolongation of surgical time, the impact on lower extremity hemodynamics in the observation group was smaller than that in the control group. From T2 to T6, the internal diameter of the femoral vein in the observation group was smaller than that in the control group, while the mean blood flow velocity and mean blood flow volume were increased compared to the control group (P<0.05). Before leaving the operating room, the patency of deep venous blood flow in the observation group was better than that in the control group (P=0.003). CONCLUSION: Placing patients in the Trendelenburg position and split-leg position with calf reverse arch during RARP for prostate cancer has a smaller impact on lower extremity hemodynamics than the low lithotomy position, and can relatively reduce the risk of postoperative deep vein thrombosis.


Assuntos
Laparoscopia , Pneumoperitônio , Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Hemodinâmica/fisiologia , Prostatectomia , Extremidade Inferior , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia
6.
ACS Appl Mater Interfaces ; 16(15): 19480-19495, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38581369

RESUMO

Light-driven soft actuators based on photoresponsive materials can be used to mimic biological motion, such as hand movements, without involving rigid or bulky electromechanical actuations. However, to our knowledge, no robust photoresponsive material with desireable mechanical and biological properties and relatively simple manufacture exists for robotics and biomedical applications. Herein, we report a new visible-light-responsive thermoplastic elastomer synthesized by introducing photoswitchable moieties (i.e., azobenzene derivatives) into the main chain of poly(ε-caprolactone) based polyurethane urea (PAzo). A PAzo elastomer exhibits controllable light-driven stiffness softening due to its unique nanophase structure in response to light, while possessing excellent hyperelasticity (stretchability of 575.2%, elastic modulus of 17.6 MPa, and strength of 44.0 MPa). A bilayer actuator consisting of PAzo and polyimide films is developed, demonstrating tunable bending modes by varying incident light intensities. Actuation mechanism via photothermal and photochemical coupling effects of a soft-hard nanophase is demonstrated through both experimental and theoretical analyses. We demonstrate an exemplar application of visible-light-controlled soft "fingers" playing a piano on a smartphone. The robustness of the PAzo elastomer and its scalability, in addition to its excellent biocompatibility, opens the door to the development of reproducible light-driven wearable/implantable actuators and lightweight soft robots for clinical applications.


Assuntos
Elastômeros , Robótica , Elastômeros/química , Poliuretanos , Ureia
7.
Nature ; 628(8009): 795-803, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38632396

RESUMO

Insects constitute the most species-rich radiation of metazoa, a success that is due to the evolution of active flight. Unlike pterosaurs, birds and bats, the wings of insects did not evolve from legs1, but are novel structures that are attached to the body via a biomechanically complex hinge that transforms tiny, high-frequency oscillations of specialized power muscles into the sweeping back-and-forth motion of the wings2. The hinge consists of a system of tiny, hardened structures called sclerites that are interconnected to one another via flexible joints and regulated by the activity of specialized control muscles. Here we imaged the activity of these muscles in a fly using a genetically encoded calcium indicator, while simultaneously tracking the three-dimensional motion of the wings with high-speed cameras. Using machine learning, we created a convolutional neural network3 that accurately predicts wing motion from the activity of the steering muscles, and an encoder-decoder4 that predicts the role of the individual sclerites on wing motion. By replaying patterns of wing motion on a dynamically scaled robotic fly, we quantified the effects of steering muscle activity on aerodynamic forces. A physics-based simulation incorporating our hinge model generates flight manoeuvres that are remarkably similar to those of free-flying flies. This integrative, multi-disciplinary approach reveals the mechanical control logic of the insect wing hinge, arguably among the most sophisticated and evolutionarily important skeletal structures in the natural world.


Assuntos
Voo Animal , Aprendizado de Máquina , Asas de Animais , Animais , Asas de Animais/fisiologia , Asas de Animais/anatomia & histologia , Fenômenos Biomecânicos , Voo Animal/fisiologia , Músculos/fisiologia , Músculos/anatomia & histologia , Robótica , Masculino , Drosophila melanogaster/fisiologia , Drosophila melanogaster/anatomia & histologia , Redes Neurais de Computação , Feminino
8.
Ann Med ; 56(1): 2337735, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38640459

RESUMO

BACKGROUND: Robot-assisted upper-limb rehabilitation has been studied for many years, with many randomised controlled trials (RCTs) investigating the effects of robotic-assisted training on affected limbs. The current trend directs towards end-effector devices. However, most studies have focused on the effectiveness of rehabilitation devices, but studies on device sizes are relatively few. GOAL: Systematically review the effect of a portable rehabilitation robot (PRR) on the rehabilitation effectiveness of paralysed upper limbs compared with non-robotic therapy. METHODS: A meta-analysis was conducted on literature that included the Fugl-Meyer Assessment (FMA) obtained from the PubMed and Web of Science (WoS) electronic databases until June 2023. RESULTS: A total of 9 studies, which included RCTs, were completed and a meta-analysis was conducted on 8 of them. The analysis involved 295 patients. The influence on upper-limb function before and after treatment in a clinical environment is analysed by comparing the experimental group using the portable upper-limb rehabilitation robot with the control group using conventional therapy. The result shows that portable robots prove to be effective (FMA: SMD = 0.696, 95% = 0.099 to.293, p < 0.05). DISCUSSION: Both robot-assisted and conventional rehabilitation effects are comparable. In some studies, PRR performs better than conventional rehabilitation, but conventional treatments are still irreplaceable. Smaller size with better portability has its advantages, and portable upper-limb rehabilitation robots are feasible in clinical rehabilitation. CONCLUSION: Although portable upper-limb rehabilitation robots are clinically beneficial, few studies have focused on portability. Further research should focus on modular design so that rehabilitation robots can be decomposed, which benefits remote rehabilitation and household applications.


Assuntos
Robótica , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Extremidade Superior , Atividades Cotidianas
9.
World J Urol ; 42(1): 245, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643347

RESUMO

PURPOSE: To provide a comprehensive update on the different techniques and outcomes of contemporary Single-Port (SP) Robotic Radical Prostatectomy (RARP) approaches. METHODS: A literature review was performed to identify cohort studies that have utilized the purpose-built SP robotic platform (Intuitive Surgical Inc., Sunnyvale, California) for RARP. All published approaches of SP-RARP were included in our review. Baseline clinical, perioperative, and postoperative oncological and functional outcomes were collected from the included studies. RESULTS: A total of 16 studies involving 1159 patients were identified. To date, five approaches of SP-RARP have been described, namely Transperitoneal, Extraperitoneal, Retzius-Sparing, Transperineal, and Transvesical. The surgical steps and clinical outcomes of the aforementioned approaches were discussed. While operating times were still faster in the Transperitoneal and Extraperitoneal cohorts, the novel and more regionalized Transvesical approach allowed for radical prostatectomy to be pursued in more patients with previous abdominal surgeries and contributed to significantly improved postoperative outcomes, including the earlier return of urinary continence and with most patients being discharged on the same day without any opioids. CONCLUSION: Based on the existing literature, the introduction of SP-RARP not only enriched the repertoire of minimally-invasive surgical treatment options for prostate cancer but also provided the opportunity for urologists to develop new techniques that can improve perioperative outcomes and postoperative quality of life. Given the limited number of patients and heterogeneity in the patient selection and reporting of postoperative outcomes, further research remains necessary to better understand the different benefits and improve patient selection algorithms for the different techniques.


Assuntos
Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Qualidade de Vida , Próstata/cirurgia , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Resultado do Tratamento
10.
Proc Natl Acad Sci U S A ; 121(16): e2314359121, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38557166

RESUMO

Suction is a highly evolved biological adhesion strategy for soft-body organisms to achieve strong grasping on various objects. Biological suckers can adaptively attach to dry complex surfaces such as rocks and shells, which are extremely challenging for current artificial suction cups. Although the adaptive suction of biological suckers is believed to be the result of their soft body's mechanical deformation, some studies imply that in-sucker mucus secretion may be another critical factor in helping attach to complex surfaces, thanks to its high viscosity. Inspired by the combined action of biological suckers' soft bodies and mucus secretion, we propose a multiscale suction mechanism which successfully achieves strong adaptive suction on dry complex surfaces which are both highly curved and rough, such as a stone. The proposed multiscale suction mechanism is an organic combination of mechanical conformation and regulated water seal. Multilayer soft materials first generate a rough mechanical conformation to the substrate, reducing leaking apertures to micrometres (~10 µm). The remaining micron-sized apertures are then sealed by regulated water secretion from an artificial fluidic system based on the physical model, thereby the suction cup achieves long suction longevity on complex surfaces but minimal overflow. We discuss its physical principles and demonstrate its practical application as a robotic gripper on a wide range of complex dry surfaces. We believe the presented multiscale adaptive suction mechanism is a powerful unique adaptive suction strategy which may be instrumental in the development of versatile soft adhesion.


Assuntos
Robótica , Água , Sucção , Desenho de Equipamento
11.
Physiother Res Int ; 29(2): e2091, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38642068

RESUMO

INTRODUCTION: Stroke has emerged as the leading cause of disability globally. The provision of long-term rehabilitation to stroke survivors poses a health care burden to many countries. Robotic devices have created a major turning point in stroke rehabilitation program. Currently, the anthropometric evidence to support the benefit of robotic rehabilitation (RR) among stroke patients is scarce. Therefore, the aim of this study was to evaluate the impact of RR on the mid-thigh circumferences of the paretic limbs in stroke patients. METHODS: Twenty stroke patients from conventional rehabilitation (CR) (n = 10) and RR (n = 10) groups were recruited through a purposive sampling method. Patients in the CR group received a two-hour session of a five-day-a-week home-based CR program for 4 weeks. Patients in the RR group received a five-day-a-week of an hour combined physiotherapy and occupational therapy session and a one-hour robotic therapy session using the HAL® Cyberdyne lower-limb, for 4 weeks. The mid-thigh circumferences of both limbs were measured on day 1 (baseline), week 2 and week 4 of rehabilitation program. RESULTS: The results revealed no statistically significant difference in the mid-thigh circumferences between the paretic (F1.05,9.44 = 1.96, p = 0.20), and the normal (F1.05,9.44 = 1.96, p = 0.20) sides in the CR group (n = 10). For the comparison between the paretic and normal sides in the RR group (n = 10), the paretic mid-thigh circumferences revealed significant time effect results (F2,18 = 11.91, p = 0.001), which were due to changes between baseline and week 2, and baseline and week 4 measurements. Interestingly, the normal mid-thigh circumferences also revealed a significant time effect (F2,18 = 6.56, p = 0.007), which is due to changes between baseline and week 4. One-way analysis of variance was employed to compare the mean average between groups due to the difference in the baseline measurements of the mid-thigh circumferences between the paretic side of the CR and the RR groups. With this adjustment, the average means mid-thigh circumferences after 4 weeks of therapy were shown to be significantly different between the CR and RR groups (F1,18 = 12.49, p = 0.02). CONCLUSION: Significant increments in the mid-thigh circumferences following RR were seen in the paretic limbs of stroke patients. Hence, this study may provide some insights into further potential research related to the benefits of RR in stroke patients.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Coxa da Perna , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/terapia , Reabilitação do Acidente Vascular Cerebral/métodos , Robótica/métodos
12.
J Robot Surg ; 18(1): 179, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38642236

RESUMO

Upper extremity complications are often a problem in robot-assisted pelvic surgery (RAPS) with the lithotomy-Trendelenburg position (LT-position). This study focused on upper extremity contact pressure (UEP) and examined the relationship between UEP and upper extremity complications. From May 2020 to April 2022 at the University of Tokyo Hospital, UEP was measured in 155 patients undergoing RARP and 20 patients undergoing RARC. A total of 350 sets of UEP were investigated in this study. UEP was measured using a portable interface pressure sensor (Palm Q, Cape CO., Kanagawa, Japan) in the preoperative lithotripsy position (L-position), preoperative LT-position, and postoperative L-position. UEP was increased in the preoperative LT-position than in the preoperative L-position (right side 5.2 mmHg vs. 17.1 mmHg, left side 5.3 mmHg vs. 17.1 mmHg, P < 0.001, respectively), and was decreased in the postoperative L-position than in preoperative LT-position (right side 17.1 mmHg vs. 10.8 mmHg, left side 17.1 mmHg vs. 10.6 mmHg, P < 0.001, respectively). Eleven upper extremities developed shoulder pain. UEP of the preoperative LT-position tended to be higher in the upper extremity exhibiting shoulder pain (25.6 mmHg (15.4-30.3) vs. 17.1 mmHg (12.0-24.4) P = 0.0901). UEP measurements may help prevent postoperative shoulder pain.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Masculino , Procedimentos Cirúrgicos Robóticos/métodos , Dor de Ombro , Extremidade Superior , Prostatectomia
13.
Bioinspir Biomim ; 19(3)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38579732

RESUMO

In the field of robotic hands, finger force coordination is usually achieved by complex mechanical structures and control systems. This study presents the design of a novel transmission system inspired from the physiological concept of force synergies, aiming to simplify the control of multifingered robotic hands. To this end, we collected human finger force data during six isometric grasping tasks, and force synergies (i.e. the synergy weightings and the corresponding activation coefficients) were extracted from the concatenated force data to explore their potential for force modulation. We then implemented two force synergies with a cable-driven transmission mechanism consisting of two spring-loaded sliders and five V-shaped bars. Specifically, we used fixed synergy weightings to determine the stiffness of the compression springs, and the displacements of sliders were determined by time-varying activation coefficients. The derived transmission system was then used to drive a five-finger robotic hand named SYN hand. We also designed a motion encoder to selectively activate desired fingers, making it possible for two motors to empower a variety of hand postures. Experiments on the prototype demonstrate successful grasp of a wide range of objects in everyday life, and the finger force distribution of SYN hand can approximate that of human hand during six typical tasks. To our best knowledge, this study shows the first attempt to mechanically implement force synergies for finger force modulation in a robotic hand. In comparison to state-of-the-art robotic hands with similar functionality, the proposed hand can distribute humanlike force ratios on the fingers by simple position control, rather than resorting to additional force sensors or complex control strategies. The outcome of this study may provide alternatives for the design of novel anthropomorphic robotic hands, and thus show application prospects in the field of hand prostheses and exoskeletons.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Mãos/fisiologia , Dedos/fisiologia , Força da Mão
14.
Asian J Endosc Surg ; 17(3): e13310, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38623612

RESUMO

Gastrointestinal stromal tumors surrounding the esophagogastric junction are often challenging to resect, with no consensus regarding the optimal surgical technique. Here in, we present a case of concurrent gastric cancer in the antrum and gastrointestinal stromal tumors adjacent to the esophagogastric junction. The patient underwent simultaneous distal gastrectomy and local resection assisted by a surgical robot, avoiding the need for total gastrectomy. The utilization of robot-assisted surgery has become an increasingly popular technique, holding promise for simplifying complex surgical procedures across diverse medical settings.


Assuntos
Tumores do Estroma Gastrointestinal , Laparoscopia , Robótica , Neoplasias Gástricas , Humanos , Neoplasias Gástricas/cirurgia , Neoplasias Gástricas/patologia , Tumores do Estroma Gastrointestinal/cirurgia , Tumores do Estroma Gastrointestinal/patologia , Laparoscopia/métodos , Gastrectomia/métodos , Estudos Retrospectivos
15.
Cir Pediatr ; 37(2): 93-98, 2024 Apr 01.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38623804

RESUMO

INTRODUCTION: We present the first case of pediatric ileocystoplasty using a purely robotic approach in Spain. CASE REPORT: 12-year-old male with neurogenic bladder of low capacity and high pressures. After failure of conservative treatment, bladder augmentation with ileum patch was decided upon. Surgery was carried out using a purely robotic approach with 4 robotic and 2 accessory ports. Surgery duration was 380 minutes in total, without intraoperative complications. He was discharged 2 weeks after cystographic control. During 32-months follow-up, he has remained continent. DISCUSSION: The minimal invasion, surgical precision and ergonomics made the robotic approach an optimal option for complex surgical techniques. Given the little availability of the robot and the low pediatric volume, its standardization is a challenge. Our accumulated experience is consistent with the current literature and shows promising surgical and esthetic results. We hope this case report will contribute to the divulgation and progressive introduction of robotic surgery in our daily lives.


INTRODUCCION: Presentamos el primer caso de abordaje robótico pediátrico puro en España. CASO CLINICO: Varón de 12 años con vejiga neurógena de escasa capacidad y altas presiones sin respuesta al tratamiento conservador, abogando por una ileocistoplastia de aumento. Se lleva a cabo un abordaje robótico puro con 4 puertos robóticos y 2 accesorios, de 380 minutos de duración total sin complicaciones intraoperatorias. Es dado de alta a las 2 semanas previo control cistográfico. Tras 32 meses de seguimiento continúa continente. COMENTARIOS: La mínima invasión, mayor precisión y ergonomía del abordaje robótico, hacen de éste una opción óptima para técnicas quirúrgicas complejas. Dada la difícil disponibilidad del robot y el escaso volumen pediátrico, resulta un reto su normalización en este campo. Nuestra experiencia coincide con la literatura, mostrando resultados quirúrgicos y estéticos prometedores. Esperamos este reporte contribuya a la difusión e introducción progresiva de la cirugía robótica en nuestra rutina.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Criança , Bexiga Urinária/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Espanha , Procedimentos Cirúrgicos Urológicos/métodos
16.
Sci Robot ; 9(89): eadi9579, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630806

RESUMO

Humanoid robots that can autonomously operate in diverse environments have the potential to help address labor shortages in factories, assist elderly at home, and colonize new planets. Although classical controllers for humanoid robots have shown impressive results in a number of settings, they are challenging to generalize and adapt to new environments. Here, we present a fully learning-based approach for real-world humanoid locomotion. Our controller is a causal transformer that takes the history of proprioceptive observations and actions as input and predicts the next action. We hypothesized that the observation-action history contains useful information about the world that a powerful transformer model can use to adapt its behavior in context, without updating its weights. We trained our model with large-scale model-free reinforcement learning on an ensemble of randomized environments in simulation and deployed it to the real-world zero-shot. Our controller could walk over various outdoor terrains, was robust to external disturbances, and could adapt in context.


Assuntos
Robótica , Humanos , Idoso , Robótica/métodos , Locomoção , Caminhada , Aprendizagem , Reforço Psicológico
17.
Asian J Endosc Surg ; 17(3): e13313, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38631698

RESUMO

There are many reports on the positional relationship between the ileocolic artery and superior mesenteric vein (SMV). However, there have been no reports of anomalous venous confluence in the ileocecal vessel area. A 69-year-old man was diagnosed with cecal cancer on a preoperative examination of a lung tumor. We planned to perform surgery for the cecal cancer. Computed tomography angiography revealed an anomalous vein confluence in the ileocolic region. We performed robot-assisted ileocecal resection. Although the small intestinal vein was misidentified as the SMV at first, we confirmed the misidentification, identified the SMV on the dorsal side of the ileocolic artery, and ligated the ileocolic vessels with precise forceps manipulation during robotic surgery. Especially for cases with vascular anomalies revealed by preoperative computed tomography angiography, robotic surgery may be useful, as flexible forceps manipulation prevents vascular injury.


Assuntos
Neoplasias do Ceco , Neoplasias , Robótica , Masculino , Humanos , Idoso , Ceco , Veias Mesentéricas/cirurgia
18.
Artigo em Inglês | MEDLINE | ID: mdl-38598401

RESUMO

Socially assistive robots (SARs) have been suggested as a platform for post-stroke training. It is not yet known whether long-term interaction with a SAR can lead to an improvement in the functional ability of individuals post-stroke. The aim of this pilot study was to compare the changes in motor ability and quality of life following a long-term intervention for upper-limb rehabilitation of post-stroke individuals using three approaches: 1) training with a SAR in addition to usual care; 2) training with a computer in addition to usual care; and 3) usual care with no additional intervention. Thirty-three post-stroke patients with moderate-severe to mild impairment were randomly allocated into three groups: two intervention groups - one with a SAR (ROBOT group) and one with a computer (COMPUTER group) - and one control group with no intervention (CONTROL group). The intervention sessions took place three times/week, for a total of 15 sessions/participant; The study was conducted over a period of two years, during which 306 sessions were held. Twenty-six participants completed the study. Participants in the ROBOT group significantly improved in their kinematic and clinical measures which included smoothness of movement, action research arm test (ARAT), and Fugl-Meyer upper-extremity assessment (FMA-UE). No significant improvement in these measures was found in the COMPUTER or the control groups. 100% of the participants in the SAR group gained improvement which reached - or exceeded - the minimal clinically important difference in the ARAT, the gold standard for upper-extremity activity performance post-stroke. This study demonstrates both the feasibility and the clinical benefit of using a SAR for long-term interaction with post-stroke individuals as part of their rehabilitation program. Trial Registration: ClinicalTrials.gov NCT03651063.


Assuntos
Robótica , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Projetos Piloto , Qualidade de Vida , Extremidade Superior , Recuperação de Função Fisiológica , Resultado do Tratamento
19.
JBJS Case Connect ; 14(2)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38635780

RESUMO

CASE: A 47-year-old orthopaedic surgeon presented with acute volar left wrist pain. He performed over 250 robot-assisted knee arthroplasties each year. Color Doppler evaluation revealed bilateral persistent median arteries and bifid median nerves, with focal occlusive thrombosis of the left median artery. He was advised rest and oral aspirin. He could return to his professional activities after 1 month. He had no recurrence of symptoms at 1 year of follow-up. CONCLUSION: Orthopaedic surgeons use vibrating hand tools on a daily basis. The possibility of hand-arm vibration syndrome must be considered in the differential diagnosis of wrist pain among orthopaedic surgeons.


Assuntos
Artroplastia do Joelho , Síndrome do Túnel Carpal , Procedimentos Cirúrgicos Robóticos , Robótica , Cirurgiões , Trombose , Masculino , Humanos , Pessoa de Meia-Idade , Nervo Mediano/cirurgia , Síndrome do Túnel Carpal/cirurgia , Artérias , Trombose/etiologia , Trombose/complicações , Artralgia/cirurgia , Artroplastia do Joelho/efeitos adversos
20.
J Med Case Rep ; 18(1): 191, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38637904

RESUMO

BACKGROUND: Renal artery pseudoaneurysm following partial nephrectomy is a rare entity, the incidence of this entity is more common following penetrating abdominal injuries, percutaneous renal interventions such as percutaneous nephrostomy(PCN) or Percutaneous nephrolithotomy (PCNL). Although rare, renal artery pseudoaneurysm can be life threatening if not managed timely, they usually present within two weeks postoperatively with usual presenting complains being gross haematuria, flank pain and/or anaemia. CASE PRESENTATION: We report case of two female patients 34 and 57 year old respectively of South Asian ethnicity, presenting with renal artery pseudoaneurysm following left sided robot assisted nephron sparing surgery for interpolar masses presenting clinically with total, painless, gross haematuria with clots within fifteen days postoperatively and their successful treatment by digital subtraction angiography and coil embolization. CONCLUSION: Renal artery aneurysm is a rare fatal complication of minimally invasive nephron sparing surgery however considering the preoperative and intraoperative risk factors for its development and prompt suspicion at the outset can be life saving with coil embolization of the bleeding arterial aneurysm.


Assuntos
Falso Aneurisma , Aneurisma , Embolização Terapêutica , Robótica , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Artéria Renal/diagnóstico por imagem , Hematúria/etiologia , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Nefrectomia/efeitos adversos , Embolização Terapêutica/efeitos adversos , Néfrons , Aneurisma/complicações , Aneurisma/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...